USGS - science for a changing world

Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Model Form #1

log10(FCB) = 0.378 + 1.13 log10(TURB)

where:

Model Calibration

Basic Data

Number of measurements: 23
Mean squared error: 0.249001
Multiple R2: 0.69
Bias correction (smearing) factor: 2.12

Explanatory Variables

VariableValueStandard error
Intercept0.3780.3512
log10(TURB) 1.130.1666

Correlation Matrix

Interceptlog10(TURB)
Intercept1-0.9552
log10(TURB) -0.95521

Reference

Notes

This model is used to compute values at this station only from 1999 through 2006, the range of time when a 6026-model turbidity sensor was used. Beginning in 2007, a 6136-model turibidty sensor was installed, resulting in a change to the model.