Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Model Form #1

log10(TSS) = 0.011 + 0.943 log10(TURB)

where:

Model Calibration

Basic Data

Number of measurements: 48
Mean squared error: 0.02944656
Multiple R2: 0.933
Bias correction (smearing) factor: 1.12666

Explanatory Variables

VariableValueStandard error
Intercept0.0110.0848
log10(TURB) 0.9430.0373

Correlation Matrix

Interceptlog10(TURB)
Intercept1-0.9564
log10(TURB) -0.95641

Reference

Notes

This model is used to compute values at this station only from 1999 through 2006, the range of time when a 6026-model turbidity sensor was used. Beginning in 2007, a 6136-model turibidty sensor was installed, resulting in a change to the model.