Model Form #1

TKN = 0.469 + 0.0234 TEMP - 6.55E-5 SC + 0.00317 TURB

where:

Model Calibration

Basic Data

Number of measurements: 20
Mean squared error: 0.0007974976
Multiple R2: 0.806
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept0.4690.196506
TEMP 0.02340.0087763
SC -0.00006550.0000341
TURB 0.003170.0006893

Correlation Matrix

InterceptTEMP SC TURB
Intercept1-0.466663-0.489197-0.480798
TEMP -0.4666631-0.393039-0.372011
SC -0.489197-0.39303910.591246
TURB -0.480798-0.3720110.5912461