Model Form #1

TP = - 0.35 + 0.29 log10(TURB)

where:

Model Calibration

Basic Data

Number of measurements: 13
Mean squared error: 0.03411409
Multiple R2: 0.81
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept-0.350.0732
log10(TURB) 0.290.0001

Correlation Matrix

Interceptlog10(TURB)
Intercept1-0.96
log10(TURB) -0.961