Model Form #1

log10(DS) = 0.49 + 0.739 log10(SC)

where:

Model Calibration

Basic Data

Number of measurements: 26
Mean squared error: 0.00273529
Multiple R2: 0.89
Bias correction (smearing) factor: 1.01

Explanatory Variables

VariableValueStandard error
Intercept0.490.1371
log10(SC) 0.7390.0537

Correlation Matrix

Interceptlog10(SC)
Intercept1-0.9972
log10(SC) -0.99721

Reference

Notes