Model Form #1
log10(CLR) =
- 0.0264 + 0.609 log10(SC)
- 0.16 log10(Q)
- 0.0359 cos(4π D / 365)
- 0.00734 sin(4π D / 365)
where:
- CLR is computed chloride, in milligrams per liter
- SC is specific conductance at 25 degrees Celsius, in microsiemens per centimeter
- Q is computed discharge, stage-discharge rating curve, in cubic feet per second
- D is day of year, in the range of integers 1 through 365
Model Calibration
Basic Data
Number of measurements: | 69 |
---|---|
Mean squared error: | 0.004225 |
Multiple R2: | 0.657 |
Bias correction (smearing) factor: | 1.01004 |
Explanatory Variables
Variable | Value | Standard error |
---|---|---|
Intercept | -0.0264 | 0.065 | log10(SC) | 0.609 | 0.0826 | log10(Q) | -0.16 | 0.0212 | cos(4π D / 365) | -0.0359 | 0.11 | sin(4π D / 365) | -0.00734 | 0.0137 |
Correlation Matrix
A correlation matrix is not available for this model. Therefore, the prediction interval was calculated by assuming that there is no correlation between the explanatory variables.
Reference
- Galloway, J., 2014, Continuous Water-Quality Monitoring and Regression Analysis to Estimate Constituent Concentrations and Loads in the Red River of the North at Fargo and Grand Forks, North Dakota, 2003–12: U.S. Geological Survey Scientific Investigations Report 2014–5064, 37 p.