Notice:Due to a lapse in appropriations, the majority of USGS websites may not be up to date and may not reflect current conditions. Websites displaying real-time data, such as Earthquake, Volcano, LANDSAT and Water information needed for public health and safety will be updated with limited support. Additionally, USGS will not be able to respond to inquiries until appropriations are enacted. For more information, please see www.doi.gov/shutdown.

Utah Real-time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

At this site, real-time estimates of water quality depend on the availability of instantaneous discharge and specific conductivity measurements. During winter months, real-time water quality estimates may not be available for this site due to effects of ice.

Model Form #1

ln(LDS) = - 6.8461 + 1.0045 ln(Q) + 1.0597 ln(SC)

where:

Model Calibration

Basic Data

Number of measurements: 88
Mean squared error: 0.97891236
Multiple R2: 0.9891
Bias correction (smearing) factor: 1.0003

Explanatory Variables

VariableValueStandard error
Intercept-6.84610.3913
ln(Q) 1.00450.0205
ln(SC) 1.05970.0318

Correlation Matrix

Interceptln(Q) ln(SC)
Intercept1-0.9942-0.996
ln(Q) -0.994210.9805
ln(SC) -0.9960.98051

Reference