Notice:Due to a lapse in appropriations, the majority of USGS websites may not be up to date and may not reflect current conditions. Websites displaying real-time data, such as Earthquake, Volcano, LANDSAT and Water information needed for public health and safety will be updated with limited support. Additionally, USGS will not be able to respond to inquiries until appropriations are enacted. For more information, please see www.doi.gov/shutdown.

Utah Real-time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

At this site, real-time estimates of water quality depend on the availability of instantaneous discharge and specific conductivity measurements. During winter months, real-time water quality estimates may not be available for this site due to effects of ice.

Model Form #1

ln(LDS) = - 6.0297 + 0.9688 ln(Q) + 0.9666 ln(SC)

where:

Model Calibration

Basic Data

Number of measurements: 91
Mean squared error: 0.00286225
Multiple R2: 0.991
Bias correction (smearing) factor: 1.0014

Explanatory Variables

VariableValueStandard error
Intercept-6.02970.1962
ln(Q) 0.96880.0114
ln(SC) 0.96660.0197

Correlation Matrix

Interceptln(Q) ln(SC)
Intercept1-0.9396-0.986
ln(Q) -0.939610.8712
ln(SC) -0.9860.87121