At this site, real-time estimates of water quality depend on the availability of instantaneous discharge and specific conductivity measurements. During winter months, real-time water quality estimates may not be available for this site due to effects of ice.
Model Form #1
ln(LDS) =
- 6.8994 + 0.9876 ln(Q)
+ 1.104 ln(SC)
where:
- LDS is computed load diss. solids, in tons per day
- Q is computed discharge, stage-discharge rating curve, in cubic feet per second
- SC is specific conductance at 25 degrees Celsius, in microsiemens per centimeter
Model Calibration
Basic Data
Number of measurements: | 16 |
---|---|
Mean squared error: | 0.01734489 |
Multiple R2: | 0.909488 |
Bias correction (smearing) factor: | 1.006 |
Explanatory Variables
Variable | Value | Standard error |
---|---|---|
Intercept | -6.8994 | 0.2178 | ln(Q) | 0.9876 | 0.0114 | ln(SC) | 1.104 | 0.022 |
Correlation Matrix
Intercept | ln(Q) | ln(SC) | |
---|---|---|---|
Intercept | 1 | -0.8958 | -0.964 |
ln(Q) | -0.8958 | 1 | 0.764 |
ln(SC) | -0.964 | 0.764 | 1 |
Reference
- U.S. Bureau of Reclamation, 2013, U.S. Bureau of Reclamation, 2013, Quality of Water Colorado River Basin Progress Report No. 24: U.S. Department of Interior, Bureau of Reclamation, Upper Colorado Region