Notice:Due to a lapse in appropriations, the majority of USGS websites may not be up to date and may not reflect current conditions. Websites displaying real-time data, such as Earthquake, Volcano, LANDSAT and Water information needed for public health and safety will be updated with limited support. Additionally, USGS will not be able to respond to inquiries until appropriations are enacted. For more information, please see www.doi.gov/shutdown.

Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on December 31, 2007.

Model Form #1

log10(FCB) = - 0.121 + 1.644 log10(TURB)

where:

Model Calibration

Basic Data

Number of measurements: 26
Mean squared error: 0.2809
Multiple R2: 0.84
Bias correction (smearing) factor: 1.85

Explanatory Variables

VariableValueStandard error
Intercept-0.1210.2668
log10(TURB) 1.6440.1446

Correlation Matrix

Interceptlog10(TURB)
Intercept1-0.921
log10(TURB) -0.9211

Reference

Notes

not an exact match for cited model, which was listed as: logFCB = 1.641log(Turb, YSI 6136)-0.121