Notice:Due to a lapse in appropriations, the majority of USGS websites may not be up to date and may not reflect current conditions. Websites displaying real-time data, such as Earthquake, Volcano, LANDSAT and Water information needed for public health and safety will be updated with limited support. Additionally, USGS will not be able to respond to inquiries until appropriations are enacted. For more information, please see www.doi.gov/shutdown.

Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on December 31, 2005.

Model Form #1

DOP = 0.0074 + 0.0024 sin(4π D) - 0.0049 cos(4π D) + 0.002 TURB + 0.0006 TChl

where:

Model Calibration

Basic Data

Number of measurements: 15
Mean squared error: 1.444E-5
Multiple R2: 0.91
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept0.00740.0024
sin(4π D) 0.00240.0015
cos(4π D) -0.00490.0015
TURB 0.0020.0001
TChl 0.00060.0001

Correlation Matrix

Interceptsin(4π D) cos(4π D) TURB TChl
Intercept1-0.1072-0.4412-0.3345-0.6567
sin(4π D) -0.107210.1755-0.14330.1132
cos(4π D) -0.44120.175510.07850.3495
TURB -0.3345-0.14330.07851-0.3757
TChl -0.65670.11320.3495-0.37571

Reference

Notes

Model assumes the same turbidity sensor is being used over all time, but that is not the case. Starting in 2005, this station switched from a YSI 6026 to a 6136, whose measurements typically are only about 2/3 of the 6026's. Thus, for 2005, this model will underestimate dissolved orthophosphorous.