Currently displayed models were developed using data from YSI 6-series sonde. Equipment was upgraded to YSI EXO sonde on 8/17/20. This will introduce additional uncertainty that may not be reflected in the computed confidence limits.
Model Form #1
TP =
0.02047 + 0.02255 sqrt(TURB)
where:
- TP is computed total phosphorus, in milligrams per liter as phosphorus
- TURB is turbidity, YSI model 6136, in formazin nephelometric units
Model Archive Summary
The model archive summary for computed total phosphorus can be viewed in pdf form here.
Model Calibration
Basic Data
| Number of measurements: | 32 |
|---|---|
| Mean squared error: | 0.00031329 |
| Multiple R2: | 0.89 |
| Bias correction (smearing) factor: | 1 |
Explanatory Variables
| Variable | Value | Standard error |
|---|---|---|
| Intercept | 0.02047 | 0.00711 | sqrt(TURB) | 0.02255 | 0.00141 |
Correlation Matrix
| Intercept | sqrt(TURB) | |
|---|---|---|
| Intercept | 1 | 0.9464 |
| sqrt(TURB) | 0.9464 | 1 |
Reference
- Lathrop, T.R., Bunch, A.R., and Downhour, M.S., 2019, Regression models for estimating sediment and nutrient concentrations and loads at the Kankakee River, Shelby, Indiana, December 2015 through May 2018: U.S. Geological Survey Scientific Investigation Report 2019–5005, 13 p.