Notice:Due to a lapse in appropriations, the majority of USGS websites may not be up to date and may not reflect current conditions. Websites displaying real-time data, such as Earthquake, Volcano, LANDSAT and Water information needed for public health and safety will be updated with limited support. Additionally, USGS will not be able to respond to inquiries until appropriations are enacted. For more information, please see www.doi.gov/shutdown.

Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Model Form #1

TKN = 0.863 + 0.00232 TURB

where:

Model Archive Summary

The model archive summary for computed total org. N + NH3 can be viewed in pdf form here.

Model Calibration

Basic Data

Number of measurements: 39
Mean squared error: 0.26286129
Multiple R2: 0.7425
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept0.8630.1105
TURB 0.002320.0002

Correlation Matrix

InterceptTURB
Intercept1-0.6696
TURB -0.66961

Reference

Notes

This model is used to compute values at this station only from 1999 through 2006, the range of time when a 6026-model turbidity sensor was used. Beginning in 2007, a 6136-model turibidty sensor was installed, resulting in a change to the model.