Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Model Form #2

PMC = e - 0.19 - 1.868 sin(2π D / 365) - 1.109 cos(2π D / 365) + 0.091 TChl
1 + e - 0.19 - 1.868 sin(2π D / 365) - 1.109 cos(2π D / 365) + 0.091 TChl









where:

Model Archive Summary

The model archive summary for computed probability of microcystin can be viewed in pdf form here.

Model Calibration

Basic Data

Number of measurements: 45
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept-0.190.647
sin(2π D / 365) -1.8680.631
cos(2π D / 365) -1.1090.542
TChl 0.0910.0525

Correlation Matrix

A correlation matrix is not available for this model. Therefore, the prediction interval was calculated by assuming that there is no correlation between the explanatory variables.

Reference

Notes

Logistic Probability Microcystin