Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on December 31, 2005.

Model Form #1

DOP = 0.0074 + 0.0024 sin(4π D) - 0.0049 cos(4π D) + 0.002 TURB + 0.0006 TChl

where:

Model Calibration

Basic Data

Number of measurements: 15
Mean squared error: 1.444E-5
Multiple R2: 0.91
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept0.00740.0024
sin(4π D) 0.00240.0015
cos(4π D) -0.00490.0015
TURB 0.0020.0001
TChl 0.00060.0001

Correlation Matrix

Interceptsin(4π D) cos(4π D) TURB TChl
Intercept1-0.1072-0.4412-0.3345-0.6567
sin(4π D) -0.107210.1755-0.14330.1132
cos(4π D) -0.44120.175510.07850.3495
TURB -0.3345-0.14330.07851-0.3757
TChl -0.65670.11320.3495-0.37571

Reference

Notes

Model assumes the same turbidity sensor is being used over all time, but that is not the case. Starting in 2005, this station switched from a YSI 6026 to a 6136, whose measurements typically are only about 2/3 of the 6026's. Thus, for 2005, this model will underestimate dissolved orthophosphorous.