Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on December 31, 2005.

Model Form #1

TIN = - 1.638 + 0.026 TURB + 0.0039 SC - 0.0278 TEMP

where:

Model Calibration

Basic Data

Number of measurements: 15
Mean squared error: 0.042849
Multiple R2: 0.94
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept-1.6380.5153
TURB 0.0260.0032
SC 0.00390.0008
TEMP -0.02780.0079

Correlation Matrix

InterceptTURB SC TEMP
Intercept1-0.0908-0.9518-0.7682
TURB -0.09081-0.0880.018
SC -0.9518-0.08810.6024
TEMP -0.76820.0180.60241

Reference

Notes

Model assumes the same turbidity sensor is being used over all time, but that is not the case. Starting in 2005, this station switched from a YSI 6026 to a 6136, whose measurements typically are only about 2/3 of the 6026's. Thus, for 2005, this model will underestimate dissolved nitrate plus nitrite.