Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on December 31, 2004.

Model Form #1

ATR = 1.075 + 0.0192 Q - 0.003 TURB

where:

Model Calibration

Basic Data

Number of measurements: 12
Mean squared error: 1.0404
Multiple R2: 0.92
Bias correction (smearing) factor: 1

Explanatory Variables

VariableValueStandard error
Intercept1.0750.3948
Q 0.01920.002
TURB -0.0030.0011

Correlation Matrix

InterceptQ TURB
Intercept1-0.151-0.4532
Q -0.1511-0.5595
TURB -0.4532-0.55951

Reference