Kansas Real-Time Water Quality

USGS station:

opens this link in a new window Go to NWISWeb
Constituent:
Time period:
Model Form:

Funding to maintain the continuous water-quality monitor at this site ended on September 30, 2005.

Model Form #1

log10(TKN) = - 0.499 + 0.287 log10(TURB)

where:

Model Calibration

Basic Data

Number of measurements: 24
Mean squared error: 0.01478656
Multiple R2: 0.66
Bias correction (smearing) factor: 1.03

Explanatory Variables

VariableValueStandard error
Intercept-0.4990.0921
log10(TURB) 0.2870.044

Correlation Matrix

Interceptlog10(TURB)
Intercept1-0.963
log10(TURB) -0.9631

Reference